EMERGENCY/AUXILIARY GENERATOR OPERATING LOG (INSPECTION TESTING)
1. ENGINE DATA
6. VOLTAGE REGULATOR
(See Note 1)
a. MAKE
b. MODEL
REMARKS
S
U
N
a. REGULATOR
MOUNTS
c. SERIAL NUMBER
d. RPM
b. RHEOSTAT CONDITION
(Corroded,connections,
e. HOUR METER
(1) START
(2) FINISH
etc.
7. AUTOMATIC TRANSFER PANEL
(See Note 1)
f. INSPECTION TEST OPERATOR
g. DATE
REMARKS
S
U
N
a. CONTACTS BURNED
h. BASE/POST
i. UNIT
b. MECHANISM BINDING
2. ALTERNATOR DATA
a. MAKE
b. MODEL
c. WIRING DAMAGED
c. SERIAL NUMBER
d. KW RATING
d. COMPONENTS
OVERHEATED
e. VOLTS
f. PHASE
8. COOLING SYSTEM
(See Note 2)
a. TEMP. DURING STANDBY
b. TEMP. DURING OPERATIONS
g. SHOP SUPERVISOR
h. DATE
c. COOLANT ADDED (Level)
d. ANTIFREEZE PROTECTION (See
Note 3)
i. LOCATION (Building)
j. RECORD IDENT NUMBER
e. FAN BELT CONDITION
f. RADIATOR AND LOUVER CON-
DITION
3. GENERAL CONDITIONS
(See Note 1)
9. LUBE OIL SYSTEM
REMARKS
S
U
N
b. OIL ADDED (Sum level)
a. OIL CHANGED (X)
a. CLEANLINESS
YES
NO
YES
NO
c. LUBE OIL CONDITION (Viscosity)
d. LEVEL IN GOVERNOR
b. EXHAUST
CONDITION
ITEM (See Note 2)
ALTERNATOR
EXCITER
c. ENGINE VIBRATION
10. KW LOAD
d. LOOSE ITEMS
(Bolts, Linkage, etc.)
PH1
PH2
PH3
11. AMPERAGE
e. TURBO VIBRATION
PH1
PH2
PH3
12. VOLTAGE
g. LOCATION OF LEAK
f. WATER LEAKS (X)
YES
NO
13. BRUSHES AND
BRUSHES RIGGING
4. FUEL SYSTEM
(See Note 1)
S
U
N
REMARKS
14. SLIP RING
CONDITION
a. FUEL LEVEL (Day Tank)
15. COMMUTATOR
CONDITION
b. FUEL LEVEL (Storage
Tank)
PH1
PH2
PH3
16. VOLTAGE
(Commercial)
c. WATER DRAINED (X)
d. FUEL LEAKS (X)
17. BATTERY CHARGER
YES
NO
YES
NO
e. LOCATION OF LEAK
a. VOLTS
b. AMPS
18. HYDROMETER
19. STARTING AIR
20. AMBIENT
5. BATTERY BANK
(See Note 1)
READING
TEMP.
(Psi)
( F)
S
U
N
REMARKS
a. CONNECTIONS
21. FILTER CHANGE
a. LUBE OIL (X)
b. FUEL (X)
c. AIR INTAKE (X)
b. CLEANLINESS
YES
NO
YES
NO
YES
NO
22. UNIT STARTED ON
(X)
c. ELECTROLYTE LEVEL
1ST TRY
2ND TRY
3RD TRY
NOT AT ALL
Use the reverse side of this form and/or 8-1/2 x 11" paper if required for additional comments, continuation of item entries (identify by item number),
and for corrective action(s) taken.
NOTE 1: Mark S for Satisfactory, U for Unsatisfactory, N for Normal, or indicate in Remarks column, as applicable.
NOTE 2: Enter data as indicated. Where no instrumentation is provided, indicate Satisfactory, Unsatisfactory, etc., as applicable.
NOTE 3: Enter Antifreeze Protection as the freeze temperature in degrees (F) as indicated on an appropriate hydrometer.
DD FORM 2744, MAY 96
LOCAL REPRODUCTION AUTHORIZED.
Adobe Professional 8.0