WATER-PLUMBING SYSTEMS INSPECTION REPORT
CASE NO.
(MANUFACTURED HOME)
NOTE TO INSPECTOR: All inspections must be completed following installation and set-up.
LOCATION OF MANUFACTURED HOME
SERIAL NO. OF MANUFACTURED HOME
NAME OF INSPECTOR
NAME AND ADDRESS OF FIRM
TELEPHONE NO. (Including Area Code)
ALL WATER PIPING HAS BEEN SUBJECTED TO A PRESSURE OF WATER OR AIR AT 100 PSI FOR 15
MINUTES WITHOUT LOSS OF PRESSURE?
1. CERTIFICATION OF WATER SYSTEM
YES
NO
The drainage and vent systems will be tested by one of the methods described below for evidence or indication of leakage.
2A. AIR TEST - The fixture traps shall be filled with water and remaining openings securely
NO LEAKS DETECTED OR EXISTING
LEAKS REPAIRED?
plugged. The entire system shall be subjected to a 2 inch (manometer) water column air pressure
YES
NO
test. If the system loses pressure, leaks may be located with smoke pumped into the system or with
soap suds spread on the exterior of the piping.
NOT APPLICABLE
2B. FLOOD LEVEL TEST - The manufactured home shall be in a level position, and the entire
NO LEAKS DETECTED OR EXISTING
LEAKS REPAIRED?
system shall be filled with water to the rim of the toilet bowl. (Tub and shower drains shall be
plugged.) After all trapped air has been released, the test shall be sustained for not less than 15
minutes without evidence of leaks. The waste piping above the level of the toilet bowl shall then be
YES
NO
tested and show no evidence of leakage when the high fixtures are filled with water and emptied
NOT APPLICABLE
simultaneously to obtain the maximum possible flow in the drain piping.
3. FIXTURE TEST - The plumbing fixtures shall be subjected to a flow test by filling them with
FIXTURES FUNCTION SATISFACTORILY?
water and checking for leaks and retarded flow while they are being emptied. Nonmetallic shower
stalls shall be tested for leaks by filling the pan with water to the top of the dam for not less than 15
minutes. All water heaters shall be equipped with approved and listed fully automatic valves or a
single valve design to provide temperature and pressure relief. Full size drain lines shall be
provided and shall discharge by gravity without being trapped and shall not have the outlet threaded.
YES
NO
FEDERAL STATUTES PROVIDE SEVERE PENALTIES FOR ANY FRAUD, INTENTIONAL MISREPRESENTATION OR CRIMINAL CONNIVANCE OR CONSPIRACY
PURPOSED TO INFLUENCE THE ISSUANCE OF ANY GUARANTY OR INSURANCE OR THE GRANTING OF ANY LOAN BY THE SECRETARY.
I certify that I have carefully inspected the above system in which I have no interest present or prospective and that I have reported herein all observed conditions.
DATE
SIGNATURE OF INSPECTOR
LICENSE NO.
VA FORM
SUPERSEDES VA FORM 26-8731a, SEP 1993,
26-8731a
JAN 2001
WHICH WILL NOT BE USED.