A. Installation
Date:
(please PRINT clearly):
Name of Job/
Permit
Installation: __________________________________________________________________
Number: ____________________
Civic Address: ______________
_____________ ________________________________________________
______________
Suite, if applicable
Civic number
Street name
NSEW, if required
Notes for Work
City: ______________________________________
Site Location: ________________________________________________
Manufacturer: ___________________________________________________________
Model: ___________________________
Serial No.: ___________________________
Size/Description.: ____________________________________________________
B. Support Information
Yes
*Note
Yes
*Note
a) The unit has an approved disconnect and overcurrent
j)
Each bathroom, or washroom, shall have at least one
receptacle within 1m of any wash basin in accordance
protection located in accordance with Rule 70-112;
with Rules 26-710(f), 26-710(g), and 26-700(11);
b) An approved distribution panel board is provided (if
k) Switches in bathrooms are located in accordance with
the panel board is located in a closet, then it must have a
Rule 30-320;
barrier installed to meet the intent of Rule 26-402);
l) Electrical heating equipment, including heat lamps, in
c) Plug fuses, if used, are of a type that are non-
bathrooms conforms to Rule 62-110 and Rule 62-202.
interchangeable with fuses of a higher rating in
(For the purposes of rule 62-110(1)(b), bathroom areas
accordance with Rule 14-204;
covered by the swing of doors and areas within 300mm of
shower rods are considered to be locations where
d) The vehicle chassis, any continuous conductive
combustible material are likely to be placed.)
piping, and the exterior metal sheathing are bonded to
ground at the panel board with a copper conductor sized
m) Dryer circuits are supplied with an approved
in accordance with Rule 70-126 (Table 41);
receptacle in accordance with Rule 26-744(3);
e) All outlet boxes and receptacles are bonded to
n) Range circuits are supplied with an approved
ground in accordance with Section 10 or protected with
receptacle in accordance with Rule 26-744(6);
GFCI in accordance with Rule 26-700(8);
o) A 120 volt smoke alarm is installed in accordance with
f) Receptacles rated at 15 amperes are on circuits
the BC building Code, and wired in conformance with
having overcurrent protection set at not more than 15
Rule 30-110;
amperes in accordance with Rule 14-600;
p) The wiring in the unit has passed an insulation test in
g) Any exterior receptacles are GFCI protected in
accordance with Rule 70-130 (Table 24) (see Appendix B
accordance with Rule 26-710(o);
note for Rule 70-130); and
h) Heating cable sets shall be protected by a GFCI
q) All wiring and equipment is in good condition
receptacle or breaker accessible for testing. Receptacles
according to rule 2-300.
located beneath the home are not considered accessible;
i) All receptacles within 1.5m of a sink are GFCI
protected in accordance with Rule 26-700(11), except for
existing split-receptacles in a kitchen;
*Note(s): (examples: o) new smoke detector installed in hallway; q) includes existing 4mx6m addition.)
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________