TABLE 4101:2-51-45 (A)
FIXTURE UNIT TABLE
FIXTURE TYPE
FIXTURE TOTAL # OF
UNIT
FIXTURES
BATHROOM GROUP
(Consisting of Water Closet, Lavatory & Bathtub or Shower Stall)
TANK WATER CLOSET
6
FLUSH-VALVE WATER CLOSET
8
BATHTUB (With or without overhead shower), Note (a)
2
BATHTUB, Note (a)
3
BIDET
3
COMBINATION SINK-AND-TRAY
3
COMBINATION SINK-AND-TRAY (with food disposal unit)
4
DENTAL UNIT or CUSPIDOR
1
DENTAL LAVATORY
1
DRINKING FOUNTAIN
1/2
DISHWASHER (Domestic), Note (b)
2
KITCHEN SINK (Domestic)
2
KITCHEN SINK (Domestic w/ Food Waste Grinder)
3
KITCHEN SINK (Domestic w/ Food Waste Grinder & Dishwasher)
3
LAUNDRY TRAY (1 or 2 compartments)
2
LAVATORY, Note (c)
1
LAVATORY, Note (c)
2
LAVATORY, Barber and/or Beauty Parlor
2
LAVATORY, Surgeon's
2
POT, Scullery, Etc., Note (b)
4
SHOWER STALL (Domestic)
2
SHOWER (Group) Per Head, Note (b)
3
SINKS
SERVICE (Clinical w/ flushing rim and valve)
8
SERVICE (Floor mounted)
3
SERVICE (P Trap)
2
SERVICE (Trap Standard)
3
SURGEON'S (Scrub)
3
URINAL, Pedestal, Syphon Jet, Blowout
8
URINAL, Wall Lip
4
URINAL STALL, Washout
4
URINAL TROUGH (Each 2 ft Section), Note (b)
2
WASHING MACHINE (Domestic) Automatic, Note (b)
2
WASH SINK (Circular or Multiple) Each set of faucets, Note (b)
2
4
WATER CLOSET, Tank-operated
WATER CLOSET, Valve-operated
8
TOTAL # OF FIXTURE UNITS - ALSO PUT ON FIRST PAGE
A Shower head over a bathtub does not increase the fixture value.
Note (a)
Note (b)
See TABLE 4101:2-51-45(B) of the Administrative Code for method of computing unit value of fixtures not
listed in TABLE 4101:2-51-45(A) or for ratings of devices with intermittent flows.
Lavatories with 1 3/4 or 1 1/2 inch trap have the same load value; larger P.O. plugs have greater flow rate.
Note (c)
Fixtures not listed in TABLE 4101:2-51-45(A) of the Administrative Code shall be estimated in accordance with TABLE
4101:2-51-45(B) of the Administrative Code.