Used Mobile Home Minimum Standards Pre-Inspection Report - Highlands County Page 2

ADVERTISEMENT

___ 5.
Bottomboard shall be rodent proofed throughout and sealed. Material used for
repairs shall be at least equivalent to the original.
___ 6.
Insulation shall be in good condition and missing insulation shall be replaced.
___ 7.
Where damage due to active water leaks is apparent, repairs shall be made.
___ 8.
Over-the-roof tie downs shall be free of damage.
___ 9.
Data plate shall indicate compliance with Wind Zone II and Climatic Zone I
requirements.
Electrical:
___ 1.
The electrical system shall be complete and any hazardous conditions shall be
corrected.
___ 2.
Electric panel shall be properly installed, complete with required breakers or
fuses and unused openings properly covered.
___ 3.
All connections shall be tight and panels shall be accessible.
___ 4.
All electrical fixtures shall be properly installed, wired and supported.
___ 5.
Aluminum conductors shall be connected to approved, listed devices.
___ 6.
Grounding conductors shall be properly secured to the correct location and/or
connector on fixtures or devices.
___ 7.
Grounding conductors shall be connected to approved, listed devics.
Plumbing:
___ 1.
The plumbing system shall include a bathroom which provides privacy and
includes a bathtub and/or shower, a toilet and a sink.
___ 2.
The plumbing system shall include a kitchen sink and approved, operating hot
water heater.
___ 3.
All plumbing fixtures shall be securely attached, and in workable condition.
___ 4.
All plumbing fixtures shall be properly vented and provided with approved,
workable traps.
___ 5.
The hot water heater shall have a relief valve with sufficient room to operate and
a minimum ¾ inch discharge extended beneath the home.
___ 6.
Drainage piping shall be complete, properly supported and not constitute a
hazard.