Ohio Residential Plan Submittal Form
Part B
Referenced Code Text
ELECTRICAL
MECHANICAL
NEC 110.3 All electrical equipment shall be installed and used in accordance with
M1401.1 Heating and cooling equipment and appliances shall be installed in
the listing requirements and manufacturer’s instructions.
accordance with the manufacturer’s installation instructions and the requirement’s of
the Residential Code.
Service
Sizing
Size of Service in Amperes:
M1401. 3 Heating and cooling equipment shall be sized based on building
Service
NEC 310-15 Conductor
Copper
Aluminum
loads calculated in accordance with ACCA Manual J or other approved
Rating
Sizes 120/240 VOLT 3-
heating and cooling calculation methodologies.
4 AWG
2 AWG
100 Amps
Wire, Single-Phase,
1 AWG
2/0 AWG
150 Amps
Dwelling
Gages of Metal Ducts & Plenums Used for Htg/Cooling
2/0
Services/Feeders
4/0 AWG
200 Amps
Types of Ducts
Size
Minimum
Equiv.
Approx.
AWG
(inches)
Thickness
Galvanized
Aluminimum
(inch)
Sheet
B & S Gage
Gage
NEC 250.50 All grounding electrodes that are present at each building
Round Ducts &
14 or less
0.013
30
26
Enclosed
over 14
0.016
28
24
or structure served shall be bonded together to form the grounding
Rectangular
Exposed
electrode system. Conductor size per NEC 250.66.
14 or less
0.016
28
24
Rectangular
over 14
0.019
26
22
NEC 250.52 Permitted Electrodes include:
Ducts
1. Metal underground water pipe in direct contact with earth for 10 feet
or more
2. Metal frame of the building
3. Concrete-encased electrode
4. Rod, pipe & plate electrodes
General Circuitry
Access & Installation
NEC 210.11 and 422.12 In addition to the branch circuits installed to
supply general illumination and receptacle outlets in dwelling units, the
following minimum requirements apply: Two 20-amp circuits for the
kitchen receptacles, One 20-amp circuit for the laundry
M1401.2 Heating and cooling equipment shall be located with respect to
receptacles, One 20-amp circuit for the bathroom receptacles and One
building construction and other equipment to permit maintenance, servicing
separate, individual branch circuit for central heating equipment
and replacement. Clearances shall be maintained to permit cleaning of
heating and cooling surfaces; replacement of filters, blowers, motors,
NEC 210.52 Receptacles installed in the kitchen to serve countertop
controls and vent connections; lubrication of moving parts; and adjustments
surfaces shall be supplied by not less than two separate small
appliance branch circuits.
NEC 210.52 Generally, receptacle outlets in habitable rooms shall be
installed so that no point measured horizontally along the floor line in
M1601.3.2 Metal ducts shall be supported by 0.5-inch (12.7 mm) wide 18-
any wall space is more than 6‘ from a receptacle outlet. A receptacle
gage metal straps or 12-gage galvanized wire at intervals not exceeding 10
shall be installed in each wall space 2 feet or more in width.
feet (3048 mm) or other approved means. Nonmetallic ducts shall be
supported in accordance with manufacturer’s installation instructions.
M1401.4 Equipment installed outdoors shall be listed and labeled for
NEC 210.52 At kitchen countertops, receptacle outlets shall be installed
outdoor installation.. Supports and foundations shall prevent excessive
so that no point along the wall line is more than 24 inch measured
horizontally from a receptacle outlet in that space. Countertop spaces
vibration, settlement or movement of equipment. Supports and foundations
shall be level and conform to manufacturer’s installation instructions.
separated by range tops, sinks or refrigerators are separate spaces.
NEC 210.52 & 406.8 At least one receptacle, accessible at grade level
and no more than 6.5' above grade, shall be installed at the front and
back of a dwelling
NEC 210.12 All branch circuits supplying 125-volt, 15 and 20 ampere
outlets in dwelling unit bedrooms shall be protected by a listed arc-fault
circuit interrupter device.
NEC 210.8 Ground-fault circuit-interrupter (GFCI) protection shall be
Plumbing
provided for all 125-volt, 15 and20 amp receptacle outlets installed
outdoors, in boathouses, garages, unfinished accessory buildings, crawl
Provide layout of plumbing fixtures on floor plan. Plumbing shall conform to
spaces at or below grade level, unfinished basements, bathrooms, at
the Residential Code.
kitchen countertops and within 6’ of the outside edge of the sink in
laundry rooms, utility rooms, and at wet-bars.