DRAFT Final Report ACWA-08-05
8 October 2008
Methods
Sampling design
Fecal coliform and water quality measurements were taken at three sites on the lower Nushagak River
between Koliganek and just downstream from New Stuyahok five times during FY08: in August,
September and October 2007, and in May and June 2008. GPS Coordinates are listed in Table 1:
Table 1.
GPS Coordinates of Lower Nushagak River Sampling Locations
Sample Site
Location Description
Latitude (º)
Longitude (º)
Site 1
Below Koliganek
59.73053
-157.27261
Site 2
Below mouth of Mulchatna River
59.62221
-157.10503
Site 3
Below New Stuyahok
59.44092
-157.31445
The sampling crew consisted of the project officer, one to two local monitors, and the boat operator.
Each of the three sample sites had a total of 9 sampling locations located along three transects. The
main site transect was located based on the information in Table 1. Three samples were taken at the
main transect—two located two feet from each bank and one “main” site at the main flow of the river.
Sample sites were located on a straight reach of the river, with a uniform channel cross section. A GPS
waypoint (minimum 20 feet accuracy) was taken at the main flow/midpoint of the stream. The distance
below/above the ordinary high water (OHW) mark was estimated at the affected bank of each site.
Per site, there were also two additional sampling transects—one located upstream, above all suspected
local human caused inputs of fecal coliform, and one located about 300 meters downstream from the
main site transect. Three sites were sampled along each of these transects— two located two feet from
each bank and one “main” site at the main flow of the river (see Figure 2).
In addition to the nine fecal coliform samples collected at each of the three sites, three sterile Deionized
water “blanks” were poured into sample bottles, for a total of 30 fecal coliform samples that were sent
to the laboratory after each of the five sampling events.
Field measurements
Water temperature
Dissolved oxygen
pH
Specific conductance
Turbidity
Barometric pressure
Laboratory samples
Fecal coliform
Page 6