Name of Facility
2012 LIFE SAFETY CODE
PART II – EXISTING APARTMENT HOUSE
MET
NOT
N/A
REMARKS
ID
MET
PREFIX
(PROMPT OR SLOW EVACUATION)
K421
High-Rise Buildings
High-rise buildings shall comply with 31.2.11.1 and 31.3.5.11.
High-rise buildings shall have emergency plans in accordance with Section
4.8 and shall include all of the following:
1. Egress procedures.
2. Methods.
3. Preferred evacuation routes for each event, including the appropriate
use of elevators.
All high-rise buildings shall be protected throughout by an approved
automatic sprinkler system in accordance with 31.3.5.2 unless the
following conditions exist:
1. An automatic sprinkler system shall not be required where every
dwelling unit has exterior exit access in accordance with 7.5.3.
2. An automatic sprinkler system shall not be required in buildings having
an approved, engineered life safety system in accordance with
31.3.5.11.4.
31.3.5.11.1, 31.3.5.11.2, 31.3.5.11.3*, 31.4.1,1, 31.4.1.2*
IF THE LEVEL OF EVACUATION DIFFICULTY IS PROMPT OR SLOW,
STOP HERE AND CONTINUE TO PART IV AND PART V.