Ship Initial Inspection Checklist (Australian Maritime Safety Authority) Page 42

ADVERTISEMENT

– Spot check some of the lifejackets, are
they in good order (straps, buckles,
lights and batteries)?
– Are the evacuation routes in compliance
with the escape plan? (SOLAS Ch II-2
Reg 13.1: means of escape so that
persons on board can safely and swiftly
escape to the lifeboat and liferaft
embarkation deck)
18.11b @ Fire/damage location:
– Is the time taken for first response
reasonable (3’ from discovery, max 12’
for first entry)?
– Is crew reporting to stations and preparing
for the duties described in the muster list?
– Is a fire pump started, using at least the
two required jets of water to show that
the system is in proper working order?
– Are fireman’s outfit and other personal
rescue equipment checked and donned?
– Are relevant communication equipment
checked?
– Is the Low Location Lighting system on?
– Is the operation of watertight doors, fire
doors, fire dampers and main inlets and
outlets of ventilation systems in the drill
area checked?
– Are necessary arrangements for
subsequent abandoning of the ship
checked?
– Is the method of entry to hot zone
satisfactory?