Building Diagrams
DIAGRAM 3
DIAGRAM 4
All split-level buildings that are slab-on-grade, either
All split-level buildings (other than slab-on-grade),
detached or row type (e.g., townhouses); with or without
either detached or row type (e.g., townhouses); with or
attached garage.
without attached garage.
Distinguishing Feature – The bottom floor (excluding
Distinguishing Feature – The bottom floor (basement
garage) is at or above ground level (grade) on at least
or underground garage) is below ground level (grade) on
1 side.*
all sides.*
DIAGRAM 5
DIAGRAM 6
All buildings elevated on piers, posts, piles, columns,
All buildings elevated on piers, posts, piles, columns,
or parallel shear walls. No obstructions below the
or parallel shear walls with full or partial enclosure
elevated floor.
below the elevated floor.
Distinguishing Feature
Distinguishing Feature
– For all zones, the area below the
– For all zones, the area below the
elevated floor is open, with no obstruction to flow of floodwaters
elevated floor is enclosed, either partially or fully. In A Zones, the
(open lattice work and/or insect screening is permissible).
partially or fully enclosed area below the elevated floor is with or
without openings** present in the walls of the enclosure. Indicate
information about enclosure size and openings in Section A –
Property Information.
* A floor that is below ground level (grade) on all sides is considered a basement even if the floor is used for living purposes, or as an office,
garage, workshop, etc.
** An "opening" is a permanent opening that allows for the free passage of water automatically in both directions without human intervention.
Under the NFIP, a minimum of 2 openings is required for enclosures or crawlspaces. The openings shall provide a total net area of not less than
1 square inch for every square foot of area enclosed, excluding any bars, louvers, or other covers of the opening. Alternatively, an Individual
Engineered Flood Openings Certification or an Evaluation Report issued by the International Code Council Evaluation Service (ICC ES) must be
submitted to document that the design of the openings will allow for the automatic equalization of hydrostatic flood forces on exterior walls. A
window, a door, or a garage door is not considered an opening; openings may be installed in doors. Openings shall be on at least 2 sides of the
enclosed area. If a building has more than 1 enclosed area, each area must have openings to allow floodwater to directly enter. The bottom of
the openings must be no higher than 1.0 foot above the higher of the exterior or interior grade or floor immediately below the opening. For more
guidance on openings, see NFIP Technical Bulletin 1.