Form Cms-2786v - Fire Safety Survey Report - Icf-Iid (Small Facilities) 2012 Life Safety Code Page 28

ADVERTISEMENT

 
 
Name of Facility
2012 LIFE SAFETY CODE
ID
NOT
PART III– NEW RESIDENTIAL BOARD & CARE OCCUPANCIES
MET
N/A
REMARKS
MET
PREFIX
K253
3. *It shall be an outside window or door operable from the inside
without the use of tools, keys, or special effort that provides a clear
opening of not less than 5.7 square feet The width shall be not less
than 20 inches. The height shall be not less than 24 inches. The
bottom of the opening shall be not more than 44 inches above the
floor. Such means of escape shall be acceptable where one of the
following criteria are met:
a.
The window shall be within 20 feet of the finished ground level.
b.
The window shall be directly accessible to fire department
rescue apparatus as approved by the authority having
jurisdiction.
The window or door shall open onto an exterior balcony
4. Windows having a sill height below the adjacent finished ground level
are that provided with a window well meet the following criteria:
a.
The window well allows the window to be fully openable.
b.
The window is not less than 9 square feet with a length and width of
not less than 36 inches.
c.
Window well deeper than 43 inches has an approved, permanently
affixed ladder or steps complying with the following:
1. The ladder or steps do not extend more than 6 inches into the
well.
2. The ladder or steps are not obstructed by the window.
5. If the sleeping room has a door leading directly to the outside of the
building with access to the finish ground level or to and exterior stairway
meeting the requirements of 32.2.2.6.3, that means of escape shall be
considered as meeting all the escape requirements for a second means.
32.2.2.3.1, 32.2.2.3.2
PROTECTION
K300
Protection – Other
List in the REMARKS section any LSC Section 32.2.3 Protection
requirements that are not addressed by the provided K-tags, but are
deficient. This information, along with the applicable Life Safety Code or
NFPA standard citation, should be included on Form CMS-2567.